head JofIMAB
Journal of IMAB - Annual Proceeding (Scientific Papers)
Publisher: Peytchinski Publishing Ltd.
ISSN: 1312-773X (Online)
Issue: 2019, vol. 25, issue4
Subject Area: Dental Medicine
-
DOI: 10.5272/jimab.2019254.2781
Published online: 11 November 2019

Original article

J of IMAB. 2019 Oct-Dec;25(4):2781-2787;
MODIFIED APPROACH TO ENSURE A UNIFORM LAYER OF ELASTIC MATERIAL FOR RELINING COMPLETE DENTURES WITH SELF CURING SILICONES
Mariana Yankova1ORCID logo Corresponding Autoremail, Bozhidar Yordanov1ORCID logo, Mariana Dimova-Gabrovska1ORCID logo, Todor Peev2ORCID logo,
1) Department of Prosthetic Dental Medicine, Faculty of Dental Medicine, Medical University, Sofia, Bulgaria.
2) Ex Deputy Rector of Medical University Sofia, Bulgaria, Private Practice, Sofia, Bulgaria.

ABSTRACT:
Setting the Problem: In the available literature, the preparation of the removable denture for the relining procedure is subjective. It is not possible to ensure a uniform thickness of the relining material in all zones, with the risk of unwanted alteration of the previously determined registrations – occlusal plane, occlusal vertical dimension and interocclusal relationship.
Purpose: The basic purpose of this article is to propose a clinically and laboratory tested method for relining complete dentures with a uniform layer of elastic material and preserving of all clinicаlly determined registrations.
Materials and Method: To create a space and ensure a uniform layer of elastic relining material, a vacuum shaped polypropylene space maintainer is fabricated. This clinical approach is illustrated by presenting a selected clinical case with retentive maxillary tuberosities and severe mandibular bone atrophy.
Results and Discussion:  The fabrication of a space maintainer for indirect relining of complete dentures with cold-curing silicones ensures a uniform layer of elastic relining material. The space maintainer is positioned in place during all clinical and laboratory steps, preserving in this way the clinically determined registrations – occlusal plane level, occlusal vertical dimension and intermaxillary relations.
Conclusions: The proposed clinical and laboratory method for relining complete dentures with cold-curing silicones is rational and effective. The space-maintainer secures a uniform layer of relining material, even distribution of masticatory pressure to the mucosal-bone biologic base and protects the denture against fracturing.

Keywords: elastic dental materials, silicone relining materials, space maintainers, direct and indirect relining techniques,

pdf - Download FULL TEXT /PDF 3302 KB/
Please cite this article as: Yankova M, Yordanov B, Dimova-Gabrovska M, Peev T. Modified Approach to Ensure a Uniform Layer of Elastic Material for Relining Complete Dentures With Self Curing Silicones. J of IMAB. 2019 Oct-Dec;25(4):2781-2787. DOI: 10.5272/jimab.2019254.2781

Corresponding AutorCorrespondence to: Dr Mariana Yankova, PhD., Department of Prosthetic Dental Medicine, Faculty of Dental Medicine, Medical University, Sofia; 1, St. G. Sofiiski blvd., Sofia, Bulgaria; E-mail: m.jankova@abv.bg

REFERENCES:
1. Anastasov IC. [Dental material science.] Sofia Smile Center Publishing House. 2013. pp. 159-161. [in Bulgarian]
2.  Boyanov BK, Krulandski VU. [Prosthetics of the Toothless Jaws]. 2013. pp. 335-38. [in Bulgarian]
3. Otto D. Klinische und experimentelle Untersuchungen weichbleibender und harter Unterfütterungskunststoffe. [Dissertation] [Medizinischen Fakultät der Friedrich-Schiller-Universität, Jena] August 2004. [in German] [Internet]
4. Hadjieva, H, Dimova M. Total rehabilitation by edentulous patients with irregularity of the alveolar ridges. J of IMAB. 2005; 11(2):50-52. [Internet]
5. Hadjieva H, Dimova M. Selective pressure impressions methods for total dentures by patients with loose and hypermobile mucosa on the alveolar ridges. Jof IMAB. 2005; 11(2):48-50. [Internet]
6. Singh K, Gupta N. Fabrication and relining of dentures with permanent silicone soft liner: A novel way to increase retention in grossly resorbed ridge and minimize trauma of knife edge and severe undercuts ridges. Dent Med Res. 2016; 4(1):24-8 [Crossref]
7. Basker RM, Davenport JC. Prosthetic Treatment of the Edentulous Patient. 4th Edition, Kindle Edition. Wiley-Blackwell. June 9, 2008.
8. Hayakawa I. Principles and practices of complete dentures: Creating the mental image of a denture. Quintessence Pub Co. 1st edition. 1999 April 1. pp.233-248.
9.  Christensen GJ. The Increased Use of Small-Diameter Implants. JADA. 2009 Jun;140(6):709-712. [Crossref]
10. Devlin H. The Review Appointment. In: Complete Dentures. Springer, Berlin, Heidelberg. 2002. Chapter 6. pp.85-94. [Crossref]
11. Kiat-Amnuay S, Gettleman L, Mekayarajjananonth T, Khan Z, Goldsmith LJ. The influence of water storage on durometer hardness of 5 soft denture liners over time. J Prosthodont. 2005 Mar;14(1):19-24. [PubMed] [Crossref]
12. MacEntee MI. The Complete Denture: A Clinical Pathway. Quintessence Publishing Co. 1999. Chapter 10. pp.88-95.
13. Mutluay MM, Oguz S, Floystrand F, Saxegaard E, Dogan A, Bek B, et al. A prospective study on the clinical performance of polysiloxane soft liners: one-year results. Dent Mater J. 2008 May;27(3):440-7. [PubMed] [Crossref]
14. Schmidt WF, Todo J, Bolender CL. Laboratory management of Molloplast-B-lined dentures. J Prosthet Dent. 1986 Jul;56(1):113-8. [PubMed] [Crossref]
15. Minami H, Suzuki S, Minesaki Y, Kurashige H, Tanaka T. In vitro evaluation of the effect of thermal and mechanical fatigues on the bonding of an autopolymerizing soft denture liner to denture base materials using different primers. J Prosthodont. 2008 Jul;17(5):392-400. [PubMed] [Crossref]
16. Huband ML. Spacer made from a visible light-cured resin for processing denture soft liners. J Prosthet Dent. 1992 Sep;68(3):542-4. [PubMed] [Crossref]
17. Polyzois GL, Kakaboura AI, Eliades GC. Curing efficiency of visible light- and dual-cured denture reliners. Int J Prosthodont. 2000 Nov-Dec;13(6):520-5. [PubMed]
18. White KC, Beckley E, Connelly ME. Trial base adapted with sealed temporary soft liner. J Prosthet Dent. 1990 Nov;64(5):618-21. [PubMed] [Crossref]
19. Bolouri A. A silicone rubber spacer for processed resilient liner in removable prosthodontics. J Prosthet Dent. 1987 Jan;57(1):117-21. [PubMed] [Crossref]
20. Kutay O. A silicone rubber spacer used to determine the optimum thickness for hard and resilient materials in complete dentures. J Prosthet Dent. 1993 Mar;69(3):329-32. [PubMed] [Crossref]
21. Reeson MG, Jepson NJ. A simple method for obtaining a uniform thickness for long-term soft denture linings. J Prosthet Dent. 1998 Mar;79(3):355-7. [PubMed] [Crossref]
22. Popov N. [Clinic of Prosthetic Dentistry.] Medicina and Fiskultura, Sofia. 1992. pp. 225, 228, 246-8. [in Bulgarian].

Received: 17 May 2019
Published online: 15 November 2019

back to Online Journal