Journal of IMAB - Annual Proceeding (Scientific Papers)
Publisher: Peytchinski Publishing Ltd.
ISSN:
1312-773X (Online)
Issue:
2021, vol. 27, issue2
Subject Area:
Dental Medicine
-
DOI:
10.5272/jimab.2021272.3676
Published online: 02 April 2021
Review article

J of IMAB. 2021 Apr-Jun;27(2):3676-3681
APPLICATION OF RESILIENT DENTURE LINING MATERIALS: LITERATURE REVIEW
Mariana Yankova1


, Todor Peev2
, Bozhidar Yordanov1
, Mariana Dimova-Gabrovska1
, Rangel Todorov1
,
1) Department of Prosthetic Dental Medicine, Faculty of Dental Medicine, Medical University - Sofia, Bulgaria.
2) Private Practice, Sofia, Bulgaria.
ABSTRACT:
Clinical cases of excessive bone resorption, presented thin, non-pliable mucosa, exostosis or painful neurogenic points require more specific methods for treatment with removable dentures. Specialized scientific literature discusses various materials and technologies for solving these problems. The use of resilient lining materials (RLMs) for partial and complete dentures is a possible solution if there are clear clinical indications and appropriate selection of the type of material.
The purpose of this review is to provide and analyze up-to-date literature data on the use of resilient materials for partial and complete denture lining.
Material and Methods: An electronic search in PubMed, Google, EBSCOhost and Science Direct databases was conducted from January to December 2019.
Results: Resilient lining materials have a variety of applications. They can be used in complete and all types of partial edentation, i.e. Classes I, II, IV and VI by Kennedy - Popov. The indications for use are different for the two RLMs groups, i.e. temporary (short-term) and permanent (long-term) lining materials. A number of authors have identified them as materials for the limited application. They consider that their use is justified only in the case of the severely atrophied alveolar ridge, in obturators and epitheses.
Conclusion: Resilient lining needs to be considered and planned in advance. It should not be used to compensate for errors in denture design. Appropriate selection of a material for the particular clinical case is of crucial importance.
Keywords: resilient denture lining materials, two-layer denture, use of resilient denture lining materials, temporary (short-term) lining, permanent (long-term) lining,
- Download FULL TEXT /PDF 1441 KB/
Please cite this article as: Yankova M, Peev T, Yordanov B, Dimova-Gabrovska M, Todorov R. Application of Resilient Denture Lining Materials: Literature Review. J of IMAB. 2021 Apr-Jun;27(1):3676-3681. DOI: 10.5272/jimab.2021272.3676
Correspondence to: Dr Mariana Yankova, PhD, Department of Prosthetic Dental Medicine, Faculty of Dental Medicine, Medical University – Sofia; 1, St. G. Sofiiski Blvd., Sofia, Bulgaria;
E-mail: marianayankova13@gmail.com
REFERENCES:
1. Yolov Tsv. [Dental treatment of the elderly in Bulgaria]. [dissertation], Medical University – Sofia; 2000. 207-210 p. [in Bulgarian]
2. Pavlova J, Uzunov T, Filchev A. [Reasons for extending the adaptation period]. Dental Medicine. 2013; 95(1):49-56. [in Bulgarian]
3. Voronov A, Lebedenko I, Voronov I. [Orthopedic treatment of patients with complete absence of teeth]. Textbook. [Moscow]; 2009; 8. 181 p. [in Russian]
4. Basker RM, Davenport JC, Thomason JM. Prosthetic Treatment of the Edentulous Patient. 5th edition. Wiley-Blackwell. April, 2011. 214-218, 224-226, 228-244 p.
5. Grant AA, Heath JR, McCord JF. Complete prosthodontics – problems, diagnosis and management. Wolfe, 1994. 123-125 p..
6. Hayakawa I. Principles and practices of complete dentures: Creating the mental image of a denture. Quintessence Pub Co. 1st edition. 1999. 233-248 p.
7. MacEntee MI. The Complete Denture. A Clinical Pathway. 1st edition. Quintessence Pub Co. January 15, 1999. 89-95 p.
8. Otto D. [Klinische und experimentelle Untersuchungen weichbleibender und harter Unterfьtterungskunststoffe.] [dissertation] [Jena] Medizinischen Fakultдt der Friedrich-Schiller-Universitet. 2004. 245 p..
9. Pisani MX, Malheiros-Segundo Ade L, Balbino KL, de Souza RF, Paranhos Hde F, et al. Oral health related quality of life of edentulous patients after denture relining with a silicone-based soft liner. Gerodontology. 2012 Jun;29(2):e474-80. [PubMed]
10. Abrams S. Complete dentures covering mandibular tori using three base materials: A case report. J Can Dent Assoc. 2000 Oct;66(9):494-6. [PubMed]
11. Abrams S. A technique for using maxillary anterior soft-tissue undercuts in denture placement: a case report. J Can Dent Assoc. 2002 May;68(5):301-4. [PubMed]
12. Popov N, Peev V, Yordanov B, Abadzhiev, Yoncheva Il. [Denture implantology]. Sofia. 2012; 43. 188, 217, 220 p. [in Bulgarian]
13. Peev T, Filchev A. [Clinic of Prosthetic Dental Medicine]. Textbook, Sofia 2008. 230-232 p.. [in Bulgarian]
14. Geering AH, Kundert M. Farbatlanten der Zahnmedizin 2 – Total- und Hybridprothetik. 2., ьberarb. und erw. Aufl. Georg Thieme Verlag; 1992. 230 p..
15. Marxkors R. (Hrsd.). Lehrbuch der zahnärztlichen Prothetik.5. Auflage. Deutscher Zahnärzte Verlag. Köln 2010. 359 p..
16. Filchev A. [Clinic of Prosthetic Dental Medicine]. Textbook. Sofia. 2014. 269-270 p.. [in Bulgarien]
17. Kawano F, Koran A 3rd, Asaoka K, Matsumoto N. Effect of soft denture liner on stress distribution in supporting structures under a denture. Int J Prosthodont.1993 Jan-Feb;6(1):43-9. [PubMed]
18. Jagger DC, Harrison A. Complete dentures--the soft option. An update for general dental practice. Br Dent J. 1997 Apr 26;182(8):313-7. [PubMed]
19. Ugrinov R, et al. [Maxillofacial and oral surgery.] [in Bulgarian] Textbook. Sofia. 2006. 122 p.
20. Chander S, Hill M, Moore D, Morrow L. Tissue conditioning materials as functional impression materials. Eur J Prosthodont Restor Dent. 2007; 15(2):67-71. [PubMed]
21. Khaledi A., Borhanihaghighi Z., Vojdani M. The effect of disinfectant agents on dimensional stability and surface roughness of a tissue conditioner material. Indian J Dent Res. 2011 Jul-Aug;22(4):499-504. [PubMed]
22. Gerdzhikov I. [Quality of life in patients with maxillary postoperative defects - analysis and optimization.] [Dissertation.] Medical University - Sofia. 2015. 150 p. [in Bulgarian]
23. Kimoto S, Kimoto K, Murakami H, Gunji A, Ito N, Kawai Y. Survival analysis of mandibular complete dentures with acrylic – based resilient liners. Gerontology. 2013 Sep;30(3):187-93. [PubMed]
24. Williamson RT. Clinical application of a soft denture liner: A case report. Quintessence Int. 1995 Jun;26(6):413-8. [PubMed]
25. Devlin H. Complete dentures: a clinical manual for the general dental practitioner. Springer-Verlag Berlin Heidelberg. 2002. 8-14, 90-91 p..
26. Garcia LT, Jones JD. Soft liners. Dent Clin North Am. 2004 Jul;48(3):709-20. [PubMed]
27. Lowe LG. Flexible denture flanges for patients exhibiting undercut tuberosities and reduced width of the buccal vestibule: a clinical report. J Prosthet Dent. 2004 Aug;92(2):128-31. [PubMed]
28. Ramasamy C, Abraham A. Prosthodontic Management of Undercut Tuberosities: A Clinical Report. JClin Diagnost Resear. 2011 Dec;5(8):1692-4.
29. Hegazy SAF, Fouad MM, Khalifa AK. Two implants retained versus soft liner retained maxillary obturators in maxillary edentulous patients with unilateral maxillary defect (Comparison of retention). J Dent Implant. 2013; 3(1):29-34. [Crossref]
30. Jurel SK, Singh R, Gupta DS. Split obturator: An innovative approach. Contemp Clin Dentist. 2011 Jul;2(3):253-5. [PubMed]
31. Kolarov R. [Sociomedical aspects of Sogren's syndrome.] [Thesis] MU, Sofia. 2004. [in Bulgarian]
32. Gajwani-Jain S, Prasad K, Hegde C, Shetty NS, Shetty M, Mody P. Prosthodontic rehabilitation of an edentulous patient affected with oral submucous fibrosis. J Indian Prosthodont Soc. 2008; 8(4):228-230.
33. Patil S, Sarode SC, Sarode GS, Bhandi S, Awan KH, Ferrari M. Prosthetic rehabilitation of oral submucous fibrosis patients: A systematic review of published case reports and case series. PLoS One. 2017 Sep 6;12(9):e0184041. [PubMed]
34. Kaira LS, Dabral E. Innovative denture – a case report. Indian Journal of Multidisciplinary Dentistry. 2013-2014; 4(1):892-895.
35. ain JK, Prabhu CR, Zahrane MA, Esawy MS, Ajagannanavar SL, Pal KS. Cu-sil dentures - a novel approach to conserve few remaining teeth: Case reports. J Int Oral Health. 2015 Aug;7(8):138-40. [PubMed]
36. Khandelwal M, Punia V. Saving one is better than none – technique for Cu – sil like denture – a case report. Ann Essen Dent. 2011 Jan-Mar;3(1):41-45. [Internet]
37. Arafa KA. Effect of Soft Liner Material on Retention of Complete Denture, (An In Vitro Study). Life Sci J. 2012; 9(2):1296-1299. [Crossref]
38. Kreve S, Dos Reis AC. Denture Liners: A Systematic Review Relative to Adhesion and Mechanical Properties. Scientific World Journal. 2019 Mar 3;2019:6913080. [PubMed]
39. Greenstein G, Cavallaro JS Jr, Tarnow DP. Clinical pearls for surgical implant dentistry: part 4. Dent Today. 2011 Feb;30(2):122, 124. [PubMed]
40. Strong SM. The spare implant overdenture: Retrofitting an existing denture to Locator attachments. General Dentistry. 2011; 59(1):20-22. [PubMed]
41. Sato Y, Okane H, Tsuga K. Finite element analysis of stress relaxation in soft denture liner. J Oral Rehabil. 2000; 27(8): 660–663. [PubMed]
42. Sadr K, Alipour J, Heidary F. Finite Element Analysis of Soft-lined Mandibular Complete Denture and its Supporting Structures. WeJ Dent Res Dent Clin Dent Prospects. 2012 Spring;6(2):37-41. [PubMed]
43. Dos Santos MBF, Da Silva Neto JP, Consani RLX, Mesquita MF. Three-dimensional finite element analysis of stress distribution in peri-implant bone with relined dentures and different heights of healing caps. J Oral Rehabilitation. 2011; 38(9):691-696. [PubMed]
44. Dos Santos MB, Consani RLX, Mesquita MF. Influence of different soft liners on stress distribution in peri-implant bone tissue during healing period. A 3D finite element analysis. J Oral Implantol. 2013, 39(5), 574-581. [PubMed]
45. Cain JR, Mitchell DL. Soft Liner-Retained, Implant-Supported Overdenture: A Technical Note. Int J Oral Maxillofac Implants. 1998Nov-Dec;13(6):857-60. [PubMed]
46. Racich MJ. Same-Day Implant Placement and Delivery of a Bar Overdenture: A Case Report. Journal of the Canadian Dental Association. 2007, 73(1), 35-39. [Internet]
47. Scheffler P. Verankerung einer Totalprothese mit Mini-Implantaten. ZWP (Zahnarzt Wirtschaft Praxis). 2013; 7-8:14-17. [Internet]
48. Taira Y, Sekine J, Sawase T, Atsuta M. Implant-retained overdenture following hemiglossectomy: a 10-year clinical case report. Journal of Oral Rehabilitation. 2006, 33(4), 313-315. [PubMed]
49. Savabi O, Ataei E, Khodaeian N. Fabricating a Soft Liner-Retained Implant-Supported Palatal Lift Prosthesis for an Edentulous Patient: A Case Report. Case Reports in Dentistry. 2012:1-4. [PubMed]
50. Kumar MN, Srinivasp P, Ramadevi S, Prasad SR, Ajayprakash P, Sudhakar M. Hypohidrotic Ectodermal Dysplasia with Anodontia: A Rare Case - Rehabilitation by Prosthetic Management. Journal of Indian Academy of Oral Medicine & Radiology. 2012; 24(4):342-345. [Internet]
51. Shekhar G, RamaRaju A, Rao C. Prosthetic rehabilitation for a patient with hypohidrotic ectodermal dysplasia: a clinical case. Braz J Oral Sci. 2010; 9(1):63-66.
52. Schnabl D, Grunert I, Schmuth M, Kapferer-Seebacher I. Prosthetic rehabilitation of patients with hypohidrotic ectodermal dysplasia: A systematic review. J Oral Rehabil. Jul;45(7):555-570. [PubMed]
53. Gollner M., Holst S., Fenner M., Schmitt J. Prosthodontic treatment of a patient with bisphosphonate-induced osteonecrosis of the jaw using a removable dental prosthesis with a heat-polymerized resilient liner: A clinical report. J Prosthet Dent. 2010; 103(4):196-201. [PubMed]
54. Apostolov NA. [The role of prosthetic adhesives in treatment with complete dentures]. [Dissertation] Medical University – Sofia. 2015. 7, 154 p. [in Bulgarian]
55. Chandrakala V, Nandeeshwar DB. Restoration of the Severely Resorbed Maxilla and Mandible using the Multicup Denture. World Journal of Dentistry (WJD). 2011 Oct-Dec;2(4):346-349. [Crossref]
56. Engelmeier RL, Gonzalez ML, Harb M. Restoration of the severely compromised maxilla using the multi-cup denture. J Prosthodont. 2008 Jan;17(1):41-6. [PubMed]
57. Vasant R, Bassi GS. Use of the multi-cup denture for a severely resorbed maxilla: a clinical report. Br Dent J. 2012 May 11;212(9):431-4. [PubMed].
Received: 14 May 2020
Published online: 02 April 2021
back to Online Journal